Supply Units
The source end of a lubrication system: reservoir, pump, filtration and the controls that start and stop delivery. Everything downstream depends on the supply unit holding pressure and flow within the band the metering devices were sized for. SES holds the range as an authorised SKF distributor, covering reservoir sizes A few litres on micro units to several hundred litres on oil units; pump types Gear, piston, vane and pneumatic reciprocating; filtration Simplex or duplex, with pressure differential indication; temperature control Immersion heaters and oil coolers. Executions include oil supply units, minimal quantity lubrication units, oil and air lubrication units, micro units, among others. It is specified most often into rolling mill circulating oil rooms and paper machine dry end bearing lubrication. Every part is genuine SKF through official channels, with designation, specification and options confirmed against your duty before it ships — supplied from Kolkata and our branch network, with breakdown cover that does not sit in an inbox.
Send an enquiry
Check Price & Availability.
Give us the size or the failed part — we reply on WhatsApp.
Trusted across Metals & Energy
Supplying India’s Industrial Names.
From integrated steel plants to power utilities and EPC majors — the works that cannot afford a counterfeit part specify through SES.










































Role
Reservoir, pump, filtration and start control
Media
Circulating oil, MQL oil, oil and air, grease
Sizing basis
Point count, line length, refill interval
Options
Heating, cooling, duplex filtration, standby pump

Where it runs.
You will find Supply Units in the parts of a plant where this particular duty actually occurs. In practice that means rolling mill circulating oil rooms, paper machine dry end bearing lubrication, machine tool spindle and slideway lubrication, and equally furnace and kiln support roller circuits, press and stamping line minimal quantity systems. What links them is the duty rather than the machine name — role: Reservoir, pump, filtration and start control. If your installation is not on that list it matters less than you would think: the operating condition decides the specification. Send us the load, the speed, the running temperature and the environment it runs in, and we will match it to the right execution in the SKF range and confirm what is in stock.
Specify it against the duty.
Specification here follows the operating condition, not the catalogue. Continuous process where a lubrication stop means a production stop — A duplex arrangement with standby pump and changeover filtration. Single-pump units are cheaper until the first bearing wipes during a filter change. Cold start in an unheated shed in the winter months — A reservoir heater with a start interlock on oil temperature. Pumping a cold, thick charge collapses suction and the pump cavitates before the bearings see anything. Bearings with a demanding cleanliness requirement — Offline or kidney-loop filtration in addition to the main filter, and specify the target cleanliness code. Full-flow filtration alone rarely holds a fine code on a system that breathes dirty air. Where two of those apply at once, specify for the harsher of the two — under-specifying is what puts the part back on the bench a month later. Send us the duty and we will confirm the execution.

Ordering this from SES.
Give the unit a return line that is larger than the supply, sloped continuously and vented. Return lines sized like feed lines back up into the housings and the reservoir level looks low while oil sits in the pipework.